VacAir Superstore supplies replacement carbon vanes for the discontinued Orion KRA 12 dry-running rotary vane vacuum pump. Although this pump is no longer manufactured, replacement vanes remain available to help industrial customers maintain existing equipment and avoid unnecessary pump replacement.
Pump Model: Orion KRA 12 (discontinued)
OEM Reference: Not available
Quantity Per Pump: 6 vanes
Vane Dimensions: 294 × 78 × 10 mm
Original Vane Height: 78 mm
Approximate Minimum Vane Height: ≈ 58 mm
Material: Replacement carbon vanes
Availability: IN STOCK
TRUSTED BY INDUSTRY FOR OVER 30 YEARS
NEED REPLACEMENT CARBON VANES?
Why waste time endlessly searching? Just give us a quick call.
No online checkout risk. No tedious forms.
Just a quick call with vacuum pump specialists
who know their products.
No Doubts – No Worries!
Get the right vanes at the right prices, with delivery arranged around how urgently you need them.
CALL THE EXPERTS NOW ☎ 0113 2088501 One quick call could save you time and money.Prefer to write to us?
✉ SEND AN ENQUIRY →URGENT ORDERS WELCOME
UK, European & Worldwide Supply
VacAir Superstore supplies replacement carbon vanes for the Orion KRA 12 dry-running rotary vane vacuum pump. Although the KRA 12 is no longer manufactured, replacement vanes can help owners continue maintaining and operating these established industrial vacuum pumps.
The Orion KRA 12 requires six replacement carbon vanes measuring 294 × 78 × 10 mm. These substantial vanes are used within the pump’s rotary vane mechanism and should be replaced with components of the correct dimensions and specification.
Each new vane has an original height of 78 mm, with an approximate minimum height of ≈ 58 mm. Regular inspection and measurement can help maintenance engineers assess vane wear and plan replacement before the components become excessively worn.
Replacement parts for discontinued vacuum pumps. Industrial vacuum pumps often remain in service long after their original production has ended. Provided the mechanical condition of the equipment is satisfactory and suitable spare parts remain available, servicing an existing pump can be a practical alternative to investing in replacement machinery.
With vanes measuring 294 mm in length, careful examination of the full running edge is particularly important. Inspect each vane for cracks, chipped corners, uneven wear and other damage. Differences in height or wear pattern across the six vanes may indicate restricted movement or internal mechanical problems.
Correct fitting and rotor preparation are essential. Before installing replacement vanes, all rotor slots should be thoroughly cleaned and examined. Remove accumulated carbon residue, foreign material and any fragments remaining from previous vane damage. Each new vane must slide freely within its slot.
VacAir has specialised in replacement carbon vanes since 1996. Our experienced team understands the challenges of maintaining older industrial vacuum pumps and can assist with replacement vane identification, technical guidance and professional servicing requirements.
For other models, visit our Orion replacement carbon vane range. Our vacuum pump engineering department can also assist with vane fitting, servicing and repairs.
TECHNICAL INFORMATION
|
ORION KRA 12 VANE FEATURES✓Replacement vanes for discontinued KRA 12 pumps
✓Six matching vanes per pump
✓294 × 78 × 10 mm vane dimensions
✓Original vane height 78 mm
✓Supports maintenance of existing equipment
✓Specialist vacuum pump engineering support
|
The Orion KRA 12 requires six replacement carbon vanes measuring 294 × 78 × 10 mm. Each vane has an original height of 78 mm and an approximate minimum height of ≈ 58 mm. Inspecting the complete vane set is especially important when maintaining older pumps.
Examine the full length of each vane. At 294 mm long, these components require careful inspection along their entire running edge. Look for cracks, chipped corners, uneven wear and differences in height between individual vanes.
Assess the condition of the existing pump. Because the KRA 12 is discontinued, the condition of the rotor, cylinder and other internal components deserves particular attention. Replacement vanes should not be fitted into damaged or contaminated rotor slots without first addressing the underlying problem.
Orion KRA 12 inspection checklist:
|
✓ Inspect all six replacement positions ✓ Measure the remaining vane heights ✓ Check the full 294 mm running edges ✓ Look for cracks and chipped corners ✓ Compare wear across the vane set |
✓ Clean all six rotor slots thoroughly ✓ Remove deposits and broken fragments ✓ Examine the cylinder running surface ✓ Investigate abnormal internal wear ✓ Confirm free movement in every slot |
CORRECT CARBON VANE ORIENTATIONBefore fitting the six Orion KRA 12 replacement carbon vanes, thoroughly clean each rotor slot along its full length. Remove carbon deposits, contamination and all remaining fragments from any previous vane failure. The higher edge is the leading edge. The chamfer follows behind, as illustrated in the VacAir fitting diagram. Confirm the direction of rotation and follow the appropriate pump servicing instructions. Each 10 mm thick replacement vane should slide smoothly within its slot. Check for binding throughout the full 294 mm length, not merely at the ends. Do not force a vane into a restricted slot. Where the rotor or cylinder shows significant wear or damage, obtain engineering advice before fitting new components. Our workshop can assist with internal inspections and repairs. |
|
VacAir Superstore supplies replacement carbon vanes and vacuum pump spare parts for industrial maintenance and repairs. We recognise that obtaining components for older equipment can become increasingly difficult, particularly when the original pump model is no longer manufactured.
Our vacuum pump spare parts range includes:
For Orion KRA 12 replacement carbon vanes, please quote the pump model and vane dimensions 294 × 78 × 10 mm. An OEM vane part number has not been established for this model, so identification should be based on the correct model and verified vane specification.
Supporting older industrial vacuum pumps. Our experience supplying replacement carbon vanes since 1996 enables us to assist customers maintaining equipment that may have been in service for many years. Where additional components are required, we can investigate genuine OEM and aftermarket availability, although some parts for discontinued pumps may be difficult to obtain.
VacAir’s engineering department provides professional replacement vane fitting, vacuum pump servicing and mechanical repairs. Our OEM-trained engineers have extensive experience with rotary vane vacuum pumps and can assist with the particular maintenance challenges associated with older industrial equipment.
Assessing the condition of the KRA 12. Before investing in replacement components for a discontinued pump, it is sensible to inspect the rotor, cylinder and associated mechanical parts. Where the internal running surfaces remain in satisfactory condition, replacement vanes may help extend the useful working life of the equipment.
Preparing the six-vane rotor. The KRA 12 uses six replacement carbon vanes measuring 294 × 78 × 10 mm. All rotor slots should be thoroughly cleaned along their entire length, with particular attention paid to accumulated carbon deposits and any restrictions that could prevent free vane movement.
Examining vane wear and damage. The original vane height is 78 mm, with an approximate minimum height of ≈ 58 mm. Check all six vanes for uneven wear, cracks, damaged corners and unusual running marks. Investigate significant differences between individual components.
Checking internal running surfaces. The cylinder and rotor should be inspected for scoring, damage and contamination, especially if the pump has experienced abnormal noise, loss of performance or previous vane breakage.
Removing debris before reassembly. All fragments of damaged carbon vanes must be removed. New vanes should slide freely within the cleaned rotor slots, without binding or requiring excessive force.
Our team can provide technical guidance to customers undertaking their own servicing or discuss professional workshop inspection and repair options. Where major components are damaged or unavailable, we can also help customers consider the practicality of repairing an existing pump against replacing the equipment.
|
VacAir supplies replacement carbon vanes for the discontinued Orion KRA 12 vacuum pump to customers throughout the UK and worldwide. We support industrial users, maintenance engineers and specialist repair companies seeking to keep established equipment operational. The KRA 12 requires six replacement carbon vanes measuring 294 × 78 × 10 mm. Please quote the pump model and dimensions when requesting a quotation, as an OEM vane reference has not been established. Order by 4pm – same-day despatch. Qualifying in-stock orders confirmed before 4pm on working days can be despatched the same day, subject to carrier arrangements. We offer competitive UK delivery and can arrange international shipping through established transport providers. Urgent requirements after 4pm? Please telephone us. We understand that an unexpected breakdown can be particularly disruptive when replacement machinery or original spare parts are difficult to obtain. We will make exceptional efforts to investigate late collection or despatch options, although same-day despatch after the normal cut-off cannot be guaranteed. For quotations, technical assistance or delivery enquiries, call 0113 2088501 or email sales@vacair-superstore.com. Please quote Orion KRA 12 and 294 × 78 × 10 mm. |
|
|
Since 1996
Vane Supply
|
Technical Help
Part Identification
|
ISO 9001:2015
Quality Management
|
OEM-Trained
Engineers
|
Replacement carbon vane specialists since 1996. VacAir has decades of experience supplying replacement carbon vanes to industrial customers, maintenance departments and vacuum pump repair businesses. We understand the importance of keeping established equipment operational, particularly when a pump model is no longer manufactured.
Replacement vanes for discontinued Orion equipment. The KRA 12 requires six replacement carbon vanes measuring 294 × 78 × 10 mm. Our team can assist customers with identifying the correct vane specification and supplying the complete replacement quantity without relying on an unverified OEM reference.
Extensive vacuum pump knowledge. Our experience covers the practical requirements of rotary vane vacuum pumps, including vane movement, rotor slot condition, cylinder wear and fitting orientation. This knowledge can be particularly valuable when original technical documentation or spare parts information is difficult to obtain.
Competitive pricing and our Price Promise. VacAir aims to provide excellent value on replacement carbon vanes. Our Price Promise applies to comparable new, in-stock replacement carbon vanes from UK suppliers for the same pump model and application, with comparable specification and quality. Genuine OEM products, clearance items, promotions, one-off and contract arrangements are excluded. Requests must be made at the quotation stage.
Customer satisfaction and externally audited quality systems. VacAir operates an ISO 9001:2015 certified quality management system, subject to external audit. We believe dependable customer service, accurate product information and honest commercial practices are essential to maintaining our reputation.
We do not fabricate product reviews, invent customer ratings or display artificial review scores on our website or provide them to search engines.
OEM-trained engineers and specialist workshop support. Our experienced engineering department can assist with replacement vane fitting, cleaning rotor slots, internal inspections, preventative servicing and repairs. We can also discuss the practical considerations involved in maintaining discontinued industrial equipment.
UK vane stock and worldwide delivery. Our UK stockholding supports both planned maintenance and urgent requirements. Qualifying in-stock orders confirmed before 4pm on working days can be despatched the same day, and international delivery can be arranged through established carriers.