Need replacement vanes urgently or need help confirming the correct vane set for your Becker DVT 2.100?
Call VacAir:
0113 2088501
Technical help and UK stock availability.
The Becker DVT 2.100 requires a complete set of 8 replacement carbon vanes, each measuring 250 × 39 × 4 mm. VacAir holds these vanes in UK stock for fast despatch.
The correct vane identification is WN 124-032. For the DVT 2.100 eight-vane set, the Becker OEM reference is 90133300008 and the VacAir replacement reference is VA901333.
VacAir has supplied replacement vacuum pump vanes and spares since 1996, supporting engineers, resellers, OEMs and end users with replacement parts, technical assistance and pump servicing.
TECHNICAL INFORMATION
|
| Pump Model | Becker DVT 2.100 |
| Quantity Per Pump | 8 vanes |
| Dimensions | 250 × 39 × 4 mm |
| New Vane Height | 39 mm |
| Minimum Wear Height | 26 mm |
| Material | Carbon |
| VacAir Part No. | VA901333 |
| Vane Identification | WN 124-032 |
| Becker OEM Reference | 90133300008 |
|
The DVT 2.100 uses eight carbon vanes which gradually wear during operation. A new WN 124-032 vane has a height of 39 mm, and the minimum wear height is 26 mm.
When replacing the vane set, inspect the pump and surrounding components for unusual wear, damage or contamination that may affect the life of the replacement vanes.
✓ Check the condition of all eight removed vanes
✓ Look for chipped, cracked or unevenly worn vanes
✓ Check that the new vanes can move correctly when fitted
✓ Inspect accessible internal surfaces for unusual wear or contamination
✓ Check other routine service items while the pump is accessible
If the old vanes show unusual or uneven wear, investigating the cause before fitting the new set can help avoid premature wear of the replacement vanes.
|
Carbon vane inspection and replacement during routine pump maintenance.
|
If you would prefer the replacement vanes to be professionally fitted, VacAir can provide engineering support as well as supplying the vane set.
VacAir has highly experienced OEM factory-trained engineers who can replace the vanes on site or carry out servicing and a full overhaul in our workshop.
We can also assist with identifying and supplying filters and other Becker spare parts required during DVT 2.100 maintenance.
|
Becker DVT 2.100 replacement vanes are held in VacAir’s UK stock for fast despatch. For urgent UK requirements, fast carrier services are available, with collection from our trade counter also possible. VacAir regularly supplies replacement carbon vanes, filters and other vacuum pump spare parts throughout the UK, Europe and worldwide. |
|
|
Since 1996
Supplying vacuum pump vanes & spares
|
40+ Years
Vacuum pump experience
|
ISO 9001:2015
Quality management system
|
OEM-Trained
Experienced pump engineers
|
VacAir has been supplying replacement vacuum pump vanes and spare parts since 1996 to OEMs, resellers, engineers, maintenance departments and end users.
Our support does not end with the supply of the eight DVT 2.100 vanes. We can help with part identification, Becker filters and spare parts, vane fitting, servicing and complete pump overhauls.
Trust VacAir Superstore for all your vacuum pump needs.
Contact us today to learn how we can help you save money and keep your operations running smoothly.