VacAir Superstore stocks and supplies replacement carbon vanes for the Busch SD 1040B dry-running rotary vane pump. We supply industrial customers, maintenance engineers and vacuum pump repair specialists with correctly specified replacement vanes, backed by decades of technical experience, competitive pricing and prompt UK despatch.
Busch OEM References: 0722000488 / 0722207620 / 0722554213* / 0722534079
VacAir Part Number: VA722000488
Quantity Per Pump: 7 vanes
Vane Dimensions: 95 × 44 × 4 mm
Original Vane Height: 44 mm
Minimum Vane Height: 34 mm
Material: Replacement carbon vanes
Availability: IN STOCK
TRUSTED BY INDUSTRY FOR OVER 30 YEARS
NEED REPLACEMENT CARBON VANES?
Why waste time endlessly searching? Just give us a quick call.
No online checkout risk. No tedious forms.
Just a quick call with vacuum pump specialists
who know their products.
No Doubts – No Worries!
Get the right vanes at the right prices, with delivery arranged around how urgently you need them.
CALL THE EXPERTS NOW ☎ 0113 2088501 One quick call could save you time and money.Prefer to write to us?
✉ SEND AN ENQUIRY →URGENT ORDERS WELCOME
UK, European & Worldwide Supply
VacAir Superstore stocks and supplies replacement carbon vanes for the Busch SD 1040B dry-running rotary vane pump. We provide industrial pump users, service engineers and maintenance departments with correctly identified replacement vanes, supported by specialist vacuum pump knowledge and a comprehensive UK vane stockholding.
The Busch SD 1040B requires seven replacement carbon vanes measuring 95 × 44 × 4 mm. Our replacement reference is VA722000488, associated with Busch OEM part numbers 0722000488, 0722207620, 0722554213* and 0722534079. Reference 0722554213 identifies the extended-life Aerodur 274 Zirkon vane version.
Monitoring vane wear is an essential part of SD 1040B maintenance. New replacement vanes have an original height of 44 mm, while the minimum permitted height is 34 mm. All seven vanes should be inspected regularly in accordance with the pump manufacturer’s instructions. Operating with vanes worn beyond the recommended limit increases the risk of vane breakage and consequential damage to the pump’s internal components.
The inspection process should consider more than vane height alone. Differences in wear between individual vanes, chipped running edges, accumulated carbon dust and restricted movement within the rotor slots can all indicate that further attention is required. Checking the cylinder surface and inlet filtration during servicing may also help identify conditions contributing to premature wear.
Replacing worn vanes as part of a planned maintenance programme can help prevent an avoidable pump breakdown. VacAir supplies the complete seven-vane SD 1040B replacement quantity and can also provide professional fitting, servicing and repairs through our own dedicated vacuum pump engineering department.
VacAir also supplies Busch vacuum pump spare parts, including filtration and maintenance components. If your SD 1040B has suffered a vane failure or requires more extensive attention, our Busch pump repair service can assist with inspection, servicing and repairs.
TECHNICAL INFORMATION
|
SD 1040B VANE FEATURES✓ Replacement vanes for Busch SD 1040B
✓ Seven matching vanes required per pump
✓ Precision dimensions 95 × 44 × 4 mm
✓ Original height 44 mm; minimum 34 mm
✓ UK stock and specialist engineering advice
|
The Busch SD 1040B uses seven dry-running rotary vanes which gradually wear during normal operation. Their condition should be assessed at the service intervals specified by the pump manufacturer. With an original height of 44 mm and a minimum permitted height of 34 mm, accurate measurement is an important part of determining when replacement is necessary.
Waiting until a vane breaks can turn a routine maintenance requirement into a more serious pump failure. A fractured vane may damage the cylinder surface, rotor or other internal components. Preventative inspection helps engineers identify excessive wear, cracks and irregular movement before these conditions lead to an unexpected stoppage.
During inspection, examine the full 95 mm vane length, measure the height of each vane and look for uneven wear patterns. Rotor slots must be clean, and every replacement vane should slide smoothly without binding. The condition of inlet filtration and the cylinder running surface should also be checked.
SD 1040B vane inspection checklist:
|
✓ Remove and inspect all seven vanes ✓ Measure vane height against the 34 mm limit ✓ Inspect each 95 mm running edge ✓ Compare wear between individual vanes ✓ Clean carbon dust and deposits from rotor slots |
✓ Examine the cylinder for scoring ✓ Inspect rotor and bearing condition ✓ Check inlet filters and internal cleanliness ✓ Remove all broken vane fragments ✓ Ensure each vane slides smoothly into its slot |
CORRECT CARBON VANE ORIENTATIONWhen installing the seven SD 1040B replacement carbon vanes, thoroughly clean the rotor slots and check their internal surfaces for wear, deposits or damage. Do not force a vane into a tight slot. Each vane should move freely when correctly fitted. The higher edge is the leading edge. The chamfer follows behind the leading edge, as illustrated in the VacAir fitting diagram. Before reassembly, inspect the cylinder running surface and ensure all carbon dust and fragments from damaged vanes have been removed. Where premature vane failure has occurred, investigate the reason rather than simply installing a replacement set. Always confirm the direction of rotor rotation and follow the manufacturer’s servicing procedures. VacAir can assist with professional vane fitting, fault investigation and workshop repairs where required. |
![]() |
* Important note — Aerodur 274 Zirkon vanes: Busch OEM reference 0722554213 identifies the Aerodur 274 Zirkon extended-life vane version. VacAir’s replacement carbon vanes are an alternative to the standard Niob vane material. Aerodur 274 Zirkon vanes can also be replaced with standard-material vanes, offering standard service life rather than the extended life of Zirkon vanes, but at a significantly lower replacement cost.
VANE FITTING & BUSCH PUMP REPAIRS →
VacAir Superstore supplies a comprehensive range of spare parts for Busch vacuum pumps, covering routine maintenance, servicing, repairs and complete pump overhauls. We supply both high-quality replacement parts from our own range and genuine Busch OEM components, providing customers with competitive options to suit their requirements.
Our Busch vacuum pump spare parts range includes:
From routine filter changes to major pump repairs, our experienced team can help identify and source the correct parts using Busch OEM references, pump model details or component information.
VacAir has supplied vacuum pump spares since 1996. Our dedicated engineering department also provides technical assistance, servicing and repairs, so customers benefit from genuine pump expertise as well as competitive spare parts supply.
VacAir’s dedicated vacuum pump engineering department provides professional Busch SD 1040B vane fitting, servicing and repairs. Our fully trained, OEM-trained engineers have extensive experience with rotary vane vacuum pumps and can undertake everything from routine vane replacement to internal inspection and mechanical repairs.
Regular maintenance can prevent avoidable pump failures. The SD 1040B has seven vanes, each originally 44 mm high, with a 34 mm minimum permitted height. Checking the vanes in accordance with the manufacturer’s servicing schedule helps identify excessive wear before a vane fractures and potentially damages the pump.
Finding the cause of premature wear. If a set of vanes has deteriorated unusually quickly, our engineers can inspect the rotor slots, cylinder running surface, filtration and relevant mechanical components. Carbon dust deposits, contamination and restricted vane movement can affect the way the vanes operate. Addressing these conditions is important before new components are installed.
Professional fitting at highly competitive rates. Customers can purchase the complete SD 1040B vane set for installation by their own maintenance engineers or arrange fitting through our specialist workshop. Where additional damage is discovered, VacAir can provide practical advice and undertake suitable repairs. Our engineering support is particularly valuable when a pump has stopped unexpectedly or experienced repeated vane problems.
|
VacAir supplies Busch SD 1040B replacement carbon vanes from our UK premises to customers across Britain and around the world. Our customers include industrial manufacturers, engineering companies, vacuum pump repair businesses and organisations responsible for maintaining production equipment. We hold replacement vanes for the SD 1040B under VacAir part number VA722000488. Each vane measures 95 × 44 × 4 mm, and seven vanes are required per pump. The associated Busch references are 0722000488, 0722207620, 0722554213* and 0722534079. Our standard-material replacement vanes also offer a more economical alternative to the extended-life Aerodur 274 Zirkon version. Order by 4pm – same-day despatch. For in-stock items ordered and confirmed before 4pm on working days, we offer same-day despatch, subject to carrier arrangements. We understand that a stopped vacuum pump can affect an entire production process, so urgent enquiries receive particular attention. If your requirement arises after the 4pm cut-off, please still contact us. Our team will make every reasonable effort to help, including investigating any remaining despatch or collection options, although same-day despatch cannot be guaranteed after the cut-off. For UK or international delivery quotations, replacement vane identification or urgent supply enquiries, telephone 0113 2088501 or email sales@vacair-superstore.com. Please quote Busch SD 1040B, VA722000488 or the relevant OEM part number. |
![]() |
|
Since 1996
Vane Supply
|
Technical Help
Part Identification
|
ISO 9001:2015
Quality Management
|
OEM-Trained
Engineers
|
Specialists in replacement carbon vanes since 1996. VacAir has spent decades supplying vacuum pump vanes and spares to industrial customers, OEMs, resellers and engineers. Our knowledge has developed through years of working with the products and the pumps in which they operate, allowing us to offer considerably more than basic parts distribution.
Correct Busch SD 1040B vanes from UK stock. We supply the seven matching 95 × 44 × 4 mm replacement carbon vanes required for the SD 1040B under VacAir reference VA722000488. Our team can assist with identifying Busch references 0722000488, 0722207620, 0722554213* and 0722534079, including the distinction between standard-material and extended-life vane versions.
Experienced vacuum pump specialists. Understanding how carbon vanes operate is just as important as identifying their dimensions. Our technical team can advise on vane inspection, correct fitting orientation, rotor slot cleanliness and the importance of replacing vanes before they wear below their recommended minimum height. For the SD 1040B, that limit is 34 mm.
Competitive prices backed by our Price Promise. VacAir works hard to provide excellent value on replacement carbon vanes without compromising the importance of correct product identification and customer support. Our Price Promise applies to qualifying comparable new, in-stock replacement carbon vanes offered by UK suppliers, subject to our published terms. Standard-material replacements may also offer substantial savings compared with extended-life Aerodur 274 Zirkon vanes.
Customer satisfaction and ISO 9001:2015 quality management. VacAir operates an ISO 9001:2015 quality management system subject to external audit. We place considerable importance on accurate information, dependable service, continual improvement and maintaining the confidence of customers who rely on us for their vacuum pump requirements.
We do not fabricate product reviews, invent customer ratings or display artificial review scores on our website or provide them to search engines. Our products, expertise and reputation have supported customers across the vacuum pump industry for decades.
Dedicated engineering support and highly competitive servicing rates. Our fully trained, OEM-trained engineers can undertake SD 1040B vane fitting, inspect the rotor and cylinder, investigate premature wear and carry out vacuum pump servicing or repairs. Customers benefit from a supplier with both replacement vane expertise and its own specialist workshop.
Prompt UK despatch and international supply. We understand the operational consequences of a failed vacuum pump. Our UK stockholding, experienced staff and established carrier arrangements allow us to support both planned maintenance and urgent replacement requirements, with worldwide shipping available.
Trust VacAir Superstore for all your vacuum pump needs.
Contact us for replacement vanes, spare parts, vacuum pumps and engineering support.